Page 5 - C-Lite Cables
P. 5

CL105 and CL105F Cables



          Standard, Armored, and Fire-Resistant Cables IEC 60092-350 SHF-2 Rated to Resist Oil, Fuels,
          Petroleum Mud.
                                                                C-Lite CL105 cables use a crosslinked jacket to achieve a smaller,

                                                                fuels, and petroleum mud and meeting the demanding
                                                                requirements of IEC 60092-350 SHF-2. Our Zerohal EN jacket is
                                                                highly flame retardant, generates low smoke, and has a low
                                                                toxicity index and reduced corrosive gas emissions.


                                                                CL105 range, with the addition of a mica-based fire barrier
                                                                wrapped around each conductor that allows continued
                                                                operation of critical safety and control circuits under some fire
                                                                conditions. CL105F cables are designed to exceed the
                                                                requirements of IEC 60331-1 or 2, delivering performance in
                                                                excess of 120 minutes at a temperature of 1000°C.


                                                   Choice of Conductor Configurations:
                               Standard                                            Armored
                                                   • Single
          FR Types: Fire Barrier to meet           • Pairs                                       FR Types: Fire Barrier to meet
          IEC60331-1 or -2                         • Triples                                     IEC60331-1 or -2
                                                   • Quad
                                                   Choice of Shielding:
                                                   • None                                        Bedding
                                                   • Overall Foil
                                                   • Individual Foil
                                                   • Overall and Individual Foil
                                                                                                 Choice of Armor:
                                                   • Overall Braid
                                                                                                 • Bare Copper
                                                   • Combination
                                                                                                 • Tinned Copper
                                                   Low-Smoke
                                                                                                 • Copper Alloy
                                                   Zero-Halogen Jacket
                                                                                                 • Galvanized Steel Wire
                                                   Flame Retardant to IEC 60332-1
                                                   and IEC 60332-3-22 Cat A
          CL90 and CL90F Cables


          Standard, Armored, and Fire-Resistant Cables IEC 60092-350 SHF-1 Jacketed.
                                                                C-Lite CL90 cables are designed to exceed the requirements of
                                                                IEC 60092-350 SHF-1. The cables are suited to applications not
                                                                requiring a jacket resistant to oil and other corrosive fluids.
                                                                CL90 cables feature a zero-halogen, low-fire hazard jacket and
                                                                are available in a wide range of conductor sizes and
                                                                configurations, including a fire resistant version.


                                                                use a mica-based fire barrier wrapped around each conductor
                                                                allowing continued operation of critical safety and control
                                                                circuits under some fire conditions. CL90F cables are designed
                                                                to exceed the requirements of IEC 60331-1 or 2, delivering
                                                                performance in excess of 120 minutes at a temperature of
                                                                1000°C.



          AEROSPACE, DEFENSE & MARINE /// RAYCHEM                                                             PAGE 5